Top Page > Products > SHEET > Products List & Properties
Properties of TERRAMAC® Sheets
  Unit Measurement
Method
Standard
(not heat resistant)
Heat Resistant Grade*
Grade     SS-300 HS-300
Before Thermoforming
HS-300
After Thermoforming
Thickness µm   300 300 300
Density g/cm³   1.26 1.33 1.33
Oxygen
Transmission Rate
ml/m²·day·MPa JIS-K7126
23°C
480 300 220
Water Vapor
Transmission Rate
g/m²·day JIS-K7129
(40°C, 90%RH)
30 14 16
Tensile
Strength
MD MPa JIS-K7127 36 56  
TD 36 22  
Breaking
Strength
MD % JIS-K7127 2.3 4.9  
TD 2.5 0.9  
Modulus of
Elongation
MD GPa JIS-K7127 2.7 3.4  
TD 2.7 3.4  
Transparency     Transpar-ent Opaque Opaque
* Thermoforming process is required for heat resistant application. PLA resin will crystallize under thermoforming process. It commonly needs 30 seconds or more time for PLA resin to crystallize enough at 110°C.